1、附表2.1 酒店变配电房1,HT1、HT2负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)一、酒店客房1标准间1203.5420.00.500.85210.00130.10247.032大床房1203.5420.00.500.85210.00130.10247.033套房1205600.00.500.85300.00185.90352.93二、公共设施4客房层照明/小动力85000.02170.00.800.85136.0084.30160.0151F酒店大堂10800.0443.20.802、0.8534.6021.4040.686避难层34700.0134.70.800.8527.8017.2032.697全日餐厅预留1001100.00.800.8580.0049.6094.138B1层后勤区47000.03141.00.500.8570.5043.7082.959预留泛光照明1100100.00.500.8550.0031.0058.8310预留广告及LED屏照明1100100.00.500.8550.0031.0058.8311预留园林用电16060.00.800.8548.0029.7056.45三、动力设备12垂直电梯24386.00.400.6034.4045.9053、7.3613垂直电梯434136.00.900.85122.4075.90144.0214变配电房22040.00.900.8536.0022.3042.3515弱电机房16060.00.800.8548.0029.7056.4516卫星电视机房15050.00.900.8545.0027.9052.9517消防控制中心18080.00.700.8056.0042.0070.0018锅炉房14545.00.400.8018.0013.5022.5019厨房预留1500500.00.700.80350.00262.50437.5020防排烟设备(最大组合)1300300.00.700.802104、.00157.50262.5021空调末端1600600.00.700.80420.00315.00525.0022消火栓接力泵275150.00.000.800.000.000.0023喷淋接力泵19090.00.000.800.000.000.0024酒店变频调速供水设备110.210.20.800.808.206.2010.2825生活水泵196.596.50.600.8057.9043.4072.3626航空障碍灯11010.00.800.808.006.0010.0027低压侧合计4442.602630.801801.803188.6728乘以同时系数0.902367.721621.5、622869.8029自然功率因素cos0.8230自动补偿(kVar)(844.00)31总安装补偿容量(kVar)(960.00)32补偿后0.952367.72777.622492.1533变压器容量(kVA)2x1600(kVA)3200.0034变压器负荷率0.7735变压器损耗24.92124.6136变压器高压侧计算负荷2392.64902.232557.10附表2.2 酒店变配电房1,HT3、HT4负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)四、空调制冷设备1酒店冷却塔26、1530.00.800.8024.0018.0030.002冷水机组26201240.00.800.80992.00744.001240.003冷水机组1316316.00.000.800.000.000.004冷却水泵275150.00.800.80120.0090.00150.005冷冻水泵275150.00.800.80120.0090.00150.006热回收循环泵11.51.50.800.801.200.901.507热水锅炉循环泵23060.00.800.8048.0036.0060.008中餐厅38250.05191.250.800.85153.0094.80179.999多功能7、厅6090.0530.450.800.8524.4015.1028.6910宴会厅、会议室及前厅52830.1528.300.800.85422.60261.90497.1711厨房预留1800800.000.400.80320.00240.00400.0012垂直电梯622132.000.400.6052.8070.4088.0013自动扶梯31545.000.700.8031.5023.6039.3614低压侧合计3674.502309.501684.702858.6715乘以同时系数1.002309.501684.702858.6716自然功率因素cos0.8017自动补偿(kVar)(8、926.00)18总安装补偿容量(kVar)(600.00)19补偿后0.952309.50758.702430.9320变压器容量(kVA)2x1600(kVA)3200.0021变压器负荷率0.7622变压器损耗24.31121.5523变压器高压侧计算负荷2333.81880.252494.29附表2.3 1#楼办公变配电房1,OT1、OT2负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)一、商务办公1办公(未包括中央空调主机)253800.082030.400.700.801421.9、301066.001776.64二、公共设施2办公公共区域93200.02186.400.700.80130.5097.90163.14338F避难层/航空障碍灯17350.0234.700.800.8527.8017.2032.694预留泛光照明1100100.000.500.8550.0031.0058.835预留广告及LED屏照明1100100.000.600.8560.0037.2070.60三、动力设备6垂直电梯661366.000.400.60146.40195.20244.007垂直电梯24386.000.400.6034.4045.9057.368车库垂直电梯24386.00010、.400.6034.4045.9057.369办公生活水泵15757.000.700.8039.9029.9049.8610 消防水泵148.548.500.000.800.000.000.0011 办公生活水转输泵14444.000.800.8035.2026.4044.0012 变配电房12020.000.900.8518.0011.2021.2013 弱电设施16060.000.900.8554.0033.5063.5514 防排烟设备(最大组合)1200200.000.000.800.000.000.0015 消控中心15050.000.800.8540.0024.8047.06四、空11、调制冷设备16 水冷变制冷剂流量机组(主机)148.5119.000.900.80107.1080.30133.8617 水冷变制冷剂流量机组(主机)547.16386.640.900.80348.00261.00435.0018 水冷变制冷剂流量机组(主机)465.82267.720.900.80240.90180.70301.1419 水冷变制冷剂流量机组(主机)436.1262.300.900.80236.10177.10295.1420 冷却水泵1115165.000.900.80148.50111.40185.6421 冷却塔1115165.000.700.80115.5086.6012、144.3622 新风机组23060.000.800.8048.0036.0060.0023 排风机组11111.000.800.808.806.6011.0024 低压侧合计4905.663344.802601.804237.5825 乘以同时系数0.903010.322341.623813.8226 自然功率因素cos0.7827 自动补偿(kVar)(1152.00)28 总安装补偿容量(kVar)(1500.00)29 补偿后0.933010.321189.623236.8530 变压器容量(kVA)2x2000(kVA)4000.0031 变压器负荷率0.8032 变压器损耗32.313、7161.8433 变压器高压侧计算负荷3042.691351.463329.32附表2.4 2#、3#楼办公变配电房1,OT3、OT4负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)一、商务办公1办公(包括空调负荷)292680.144097.520.700.852868.301777.603374.46二、公共设施2办公公共区域64100.02128.200.700.8589.7055.60105.5335层架空层/航空障碍灯17280.0234.560.800.8527.6017.1014、32.474预留泛光照明16060.000.500.8530.0018.6035.305预留广告及LED屏照明16060.000.600.8536.0022.3042.356热水器41560.000.200.8512.007.4014.10三、动力设备6垂直电梯1040400.000.400.60160.00213.30266.647变配电房12020.000.900.8518.0011.2021.208弱电设施16060.000.900.8554.0033.5063.559防排烟设备(最大组合)1200200.000.000.800.000.000.0010 消控中心15050.000.8015、0.8040.0030.0050.0011 生活水泵162.562.500.800.8050.0037.5062.5012 低压侧合计5232.783385.602224.104050.7913 乘以同时系数0.903047.042001.693645.7114 自然功率因素cos0.8315 自动补偿(kVar)(1001.00)16 总安装补偿容量(kVar)(1200.00)17 补偿后0.953047.041000.693207.1518 变压器容量(kVA)2x2000(kVA)4000.0019 变压器负荷率0.8020 变压器损耗32.07160.3621 变压器高压侧计算负荷316、079.111161.053290.74附表2.5 商业变配电房1-3,RT1-RT8负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)1地下二、三层非人防停车场794180.021588.360.700.851111.90689.101308.122B2设备房10000.0220.000.800.8516.009.9018.823商铺259170.133369.210.700.852358.401461.602774.594餐饮135310.263518.060.700.802462.60117、847.003078.285公共走廊(含中庭)340000.031020.000.700.85714.00442.50840.006设备房11500.0223.000.800.8518.4011.4021.657预留园林照明1100100.000.500.8550.0031.0058.838预留泛光照明1100100.000.500.8550.0031.0058.839预留广告及LED屏照明1400400.000.700.85280.00173.50329.4010热水器1300300.000.200.8560.0037.2070.6014垂直电梯1422308.000.400.60123.218、0164.30205.3615垂直电梯2714.000.400.605.607.509.3616垂直电梯31648.000.400.6019.2025.6032.0017自动扶梯4715705.000.700.80493.50370.10616.8618生活水泵1120120.000.700.8084.0063.00105.0019排水泵(最大组合)1300300.001.000.80300.00225.00375.0020裙楼防护冷却供水设备15555.000.000.800.000.000.0021变配电房520100.000.900.8590.0055.80105.8922消防控制中心119、150150.000.900.85135.0083.70158.8423弱电机房1120120.000.900.85108.0066.90127.0424防排烟设备(最大组合)1300300.000.000.800.000.000.0025空调末端116001600.000.700.851120.00694.101317.6426AV设备1200200.000.800.85160.0099.20188.2628低压侧合计14458.639759.806589.4011775.9929乘以同时系数0.908783.825930.4610598.3930自然功率因素cos0.8231自动补偿(kV20、ar)(3044.00)32总安装补偿容量(kVar)(4320.00)33补偿后0.958783.822886.469245.9334变压器容量(kVA)2x2000+4x1600+2x800(kVA)12000.0035变压器负荷率0.7736变压器损耗92.46462.3037变压器高压侧计算负荷8876.283348.769486.96附表2.6 商业变配电房4,RT9,RT10负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)1SPA59000.251475.000.700.851021、32.50639.901214.712超市冷水机组1475475.000.800.80380.00285.00475.003超市冷却水泵19090.000.800.8072.0054.0090.004超市冷冻水泵19090.000.800.8072.0054.0090.005超市冷却塔12222.000.800.8017.6013.2022.006电影院冷水机组2201.5403.000.800.80322.40241.80403.007电影院冷冻水泵31133.000.800.8026.4019.8033.008商业冷却水泵4200800.000.800.80640.00480.00800.22、009商业冷冻水泵4200800.000.800.80640.00480.00800.0010商业冷却塔918.5166.500.800.80133.2099.90166.5011低压侧合计4354.503336.102367.604090.8512乘以同时系数0.903002.492130.843681.7713自然功率因素cos0.8114自动补偿(kVar)(1144.00)15总安装补偿容量(kVar)(1200.00)16补偿后0.953002.49986.843160.5117变压器容量(kVA)2x2000(kVA)4000.0018变压器负荷率0.7919变压器损耗31.61123、58.0320变压器高压侧计算负荷3034.101144.873242.91附表2.7 商业变配电房5,RT11,RT12负荷计算表序 用电设备组名称数量/面积单位容量额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)1电影院47000.15705.000.700.85493.50305.80580.572地下二、三层人防区停车场400000.02800.000.700.85560.00347.10658.853地上停车场(B1)200000.02400.000.700.85280.00173.50329.404超市用电100000.1224、1200.000.800.85960.00595.001129.445超市加压、排烟1200200.000.000.850.000.000.006超市空调末端1200200.000.700.85140.0086.80164.727超市热水器1100100.000.200.8520.0012.4023.538变配电房12020.000.900.8518.0011.2021.209弱电设施16060.000.900.8554.0033.5063.5510防排烟设备(最大组合)1200200.000.000.800.000.000.0011消防监控中心15050.000.800.8040.0030.25、0050.0012低压侧合计3935.002453.501520.602886.5013乘以同时系数0.902208.151368.542597.8514自然功率因素cos0.8515自动补偿(kVar)(643.00)16总安装补偿容量(kVar)(960.00)17补偿后0.952208.15725.542324.2918变压器容量(kVA)2x1600(kVA)3200.0019变压器负荷率0.7220变压器损耗23.24116.2121变压器高压侧计算负荷2231.39841.752384.88附表2.8 商业变配电房6,RT13,RT14负荷计算表序 用电设备组名称数量/面积单位容量26、额定容量需用系数功率因数计算负荷号nkW/nkWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)1百货用电0.12160001920.000.800.851536.00951.901807.042加压、排烟3001300.000.000.850.000.000.003变配电房20120.000.900.8518.0011.2021.204空调末端3001300.000.700.85210.00130.10247.035热水器1001100.000.200.8520.0012.4023.536变配电房12020.000.900.8518.0011.2021.207弱电设施16060.027、00.900.8554.0033.5063.558低压侧合计2720.001856.001150.302183.569乘以同时系数0.901670.401035.271965.2010自然功率因素cos0.8511自动补偿(kVar)(487.00)12总安装补偿容量(kVar)(750.00)13补偿后0.951670.40548.271758.0814变压器容量(kVA)2x1250(kVA)2500.0015变压器负荷率0.7016变压器损耗17.5887.9017变压器高压侧计算负荷1687.98636.171803.88附表2.9 住宅变配电房1,T1,T2负荷计算表附表2.10 住28、宅变配电房2,T3,T4负荷计算表序 用户名称住宅层数面积数量单位容量 负荷容量 需用系数 功率因数计算负荷序 用户名称住宅层数面积数量单位容量负荷容量需用系数功率因数计算负荷号(不计避难层)(m2)n(kW)kWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)号(不计避难层)(m2)n(kW)kWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)14栋(D型)住宅A户530层251712511.6290.716栋(C型)住宅A户532层271872712.7343.324栋(D型)住宅B户530层262252615.3397.826栋(C型)住宅B户532层2823328129、5.8443.635栋(D型)住宅A户530层251712511.6290.737栋(C型)住宅A户532层271872712.7343.345栋(D型)住宅B户530层262252615.3397.847栋(C型)住宅B户532层282332815.8443.65住宅小计1377.00.600.80826.20619.701032.785住宅小计1573.90.600.80944.36708.301180.476消防电梯230.060.00.220.5513.2020.0023.966消防电梯230.060.00.220.5513.2020.0023.967非消防电梯430.0120.00.30、220.5526.4040.1048.017非消防电梯430.0120.00.220.5526.4040.1048.018加压风机90.00.000.800.000.000.008加压风机90.00.000.800.000.000.009梯间照明210.020.00.700.8014.0010.5017.509梯间照明210.020.00.700.8014.0010.5017.5010低压侧合计1667.0879.80690.301118.2910低压侧合计1863.9997.96778.901265.9411乘以同时系数1.00879.80690.301118.2911乘以同时系数1.00931、97.96778.901265.9412自然功率因素cos0.7812自然功率因素cos0.7813自动补偿(kVar)(316.00)13自动补偿(kVar)(354.00)14总安装补偿容量(kVar)(300.00)14总安装补偿容量(kVar)(300.00)15补偿后0.92879.80374.30956.1115补偿后0.92997.96424.901084.6516变压器容量2x630(kVA)1260.0016变压器容量2x800(kVA)1600.0017变压器负荷率0.7517变压器负荷率0.6718变压器损耗9.5647.8118变压器损耗10.8554.2319变压器高32、压侧计算负荷889.36422.11984.4519变压器高压侧计算负荷1008.80479.131116.80附表2.11 住宅变配电房3,T5,T6负荷计算表附表2.12 住宅变配电房4,T7,T8负荷计算表序 用户名称住宅层数面积数量单位容量 负荷容量 需用系数 功率因数计算负荷序 用户名称住宅层数面积数量单位容量负荷容量需用系数功率因数计算负荷号(不计避难层)(m2)n(kW)kWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)号(不计避难层)(m2)n(kW)kWKxCOSPjs(kW)Qjs(kvar)Sjs(kVA)18栋(B型)住宅A户533层282512817.1433、77.919栋(A型)住宅A户533层294182928.4824.328栋(B型)住宅B户533层292512917.1495.029栋(A型)住宅B户533层283782825.7719.73住宅小计972.90.600.80583.73437.80729.663住宅小计1544.00.600.80926.40694.801158.004消防电梯130.030.00.220.556.6010.0011.984消防电梯130.030.00.220.556.6010.0011.985非消防电梯230.060.00.220.5513.2020.0023.965非消防电梯230.060.00.2234、0.5513.2020.0023.966加压风机45.00.000.800.000.000.006加压风机45.00.000.800.000.000.007梯间照明110.010.00.700.807.005.308.787梯间照明110.010.00.700.807.005.308.788生活水泵152.052.00.700.8036.4027.3045.508低压侧合计1689.0953.20730.101200.699低压侧合计1169.9646.93500.40817.879乘以同时系数1.00953.20730.101200.6910乘以同时系数1.00646.93500.4081735、.8710自然功率因素cos0.7911自然功率因素cos0.7911自动补偿(kVar)(325.00)12自动补偿(kVar)(225.00)12总安装补偿容量(kVar)(378.00)13总安装补偿容量(kVar)(300.00)13补偿后0.92953.20405.101035.7114补偿后0.92646.93275.40703.1114变压器容量2x630(kVA)1260.0015变压器容量2x500(kVA)1000.0015变压器负荷率0.8216变压器负荷率0.7016变压器损耗10.3651.7917变压器损耗7.0335.1617变压器高压侧计算负荷963.56456.891066.3918变压器高压侧计算负荷653.96310.56723.95变压器容量统计表技术经济指标表装设变压器容量合计项目kVAkVA住宅2*500+4*630+2*8005120低层办公(A、B座)2*20004000低区酒店和配套、后勤4*16006400中区和高层办公2*20004000商业和地下室2*800+2*1250+6*1600+4*200021700商业10kV空调主机4*10504200共计45420
CAD图纸
上传时间:2023-09-04
330份